PHOTONIC INSECTICIDES — FEA CONTOUR REVEALS 23 October 2026 DELIVERABLES photonic_engineering_film_FEA.mp4 — the original 32-second story, expanded to 50 seconds with structural and thermal reveals. analysis_reveals.mp4 — 18-second standalone insert, silent, 1600x900 at 24fps. review.html — offline-capable local review page with a draggable registered comparison and three cases. photonic_fea_studies.blend — editable frozen study geometry, scalar-field attributes and named cameras. mount_clean.png / mount_stress.png — matching material and recovered stress renders. thermal_clean.png / thermal_first_pulse.png / thermal_pulse_train.png — matching temperature study renders. analysis/ — input geometry, field arrays, VTK postprocessing exports, results, refinement history and sensitivity runs. source/ — the scripts used to extract, solve, map, render and compose. VISUAL DIRECTION These are false-color finite-element contour renders, implemented as scalar-field shading on 3D geometry. The structure has a real tetrahedral boundary mesh over the recovered carrier stress field. Temperature is sampled from the actual transient FE mesh onto a subdivided CAD surface. The temperature display tessellation is not passed off as the solver mesh. No hand-painted stress or heat gradients are used. The frozen comparison cameras, geometry poses and registration are identical within each case. The mounting components are separated for visibility, while the mechanics are solved in the assembled configuration. Geometry is shown undeformed. The wipe moves across a fixed computed result; its screen time is not physical heating time. The first-pulse and repeated-pulse views explicitly show different simulation timestamps and scales. Stress colors are relative to the legend, not failure colors. No design-certified, safe, or yield-pass badge is used. STRUCTURAL STUDY Part: the lower Removable carrier, 87 x 68 x 10 mm nominal envelope with its actual evaluated bevel geometry. The convex surface was extracted from Blender in the drone frame; coordinates were snapped to 0.1 micrometre to remove transform float noise before volumetric Delaunay meshing. The actual rounded carrier volume is 55590.40 mm3, giving 150.09 g at assumed aluminum density 2700 kg/m3. Solver: scikit-fem 12.0.2, 3D linear-elastic quadratic tetrahedra. Selected mesh has 9,312 tetrahedra and 47,652 displacement degrees of freedom. Material: assumed isotropic 6061-T6 aluminum, E=69 GPa, nu=0.33. This material is a design assumption for the previously unassigned graphite-looking carrier, not a test certificate or confirmation of a fabricated part. Load: 0.35 kg attached payload plus carrier self-inertia, equivalent acceleration 3g down and 1g lateral. The payload COM is 60 mm below the carrier centre. This is a separate design load case, not a load extracted from the earlier MuJoCo flight trace. Traction across the bonded lower flat face transfers the correct resultant force and offset moment. Applied force is [4.905922839604379, 0.0, -14.717768518813134] N; pitch moment is -0.206010 Nm. Supports: four 6 mm-radius / 11 mm-high isolator seats, represented by a linear normal/shear foundation. Nominal assumed elastomer E=2 MPa, nu=0.49; per-pad normal stiffness 20563.2 N/m, shear stiffness 6900.4 N/m. Patch integration is area-normalized to the same physical disk area on every mesh. These are equivalent springs, not a nonlinear solid-rubber FE model. Selected result: maximum translation 0.3624 mm; volume-weighted 95th-percentile element von Mises stress 0.04435 MPa. The displayed color is volume-weighted nodal recovery, with its own 0–0.07 MPa legend. The local quadrature peak 0.2519 MPa is mesh-sensitive and is not used as an allowable or as proof of strength. Refinement changes translation 0.0145% and P95 stress 0.945%. Force and moment residuals are 2e-08 and 1.3e-07 relative. The 1–5 MPa assumed elastomer sensitivity changes translation from 0.145 to 0.725 mm. This is the dominant practical uncertainty. Most motion is support compliance; it should not be read as the metal carrier bending by that amount. The current 10 mm carrier is relatively thick and about 150 g; weight reduction is a future design opportunity, not a change silently made for this visualization. The hardpoint, bolt preload/contact, slip, isolator retention, nonlinear rubber, fatigue and flight vibration are not qualified. The model does not establish optical pointing stability under rotor vibration. A perfectly clamped reference model and its failed displacement refinement check are retained separately in clamped_reference_results.json / structural_refinement_history.json. It was replaced by the physically more appropriate compliance model, without relaxing the numerical thresholds. No clamped reference pass is claimed. TRANSIENT THERMAL STUDY 3D P1 tetrahedral heat conduction, lumped FE heat capacity, event-aligned implicit Euler integration. The nominal model has 9,953 nodes and 37,228 tetrahedra. The domain follows the CAD heat-path envelopes: copper saddle and bridge, fitted package, interface layers, chamber surrogate, aluminum carrier and 11 fins. The bore/package cross-section and edges are voxelized; bevels are retained in the display mesh. The old display-only TO9 can orientation is not used as a detailed hardware definition. This study uses a homogenized 9 mm-diameter / 8 mm-long package fitted into the saddle bore and aligned with the optical unit axis. Pulse scenario: original 1 W optical / 9.8 W electrical concept. Heat loss while on is 8.8 W. A 100 ms pulse therefore deposits 0.88 J of heat and corresponds to 0.10 J optical energy. The train is 100 ms on once per second for 60 pulses. It does not represent the website's 3.5 J emitter and does not establish insect efficacy. Ambient: 25 C. Nominal convection h=20 W/m2K only on the externally exposed fin region, h=5/50 sensitivity. No airflow CFD or measured rotor-wash coefficient is claimed. Internal surfaces are adiabatic. Copper k=394 W/mK, rho=8920 kg/m3, cp=394 J/kgK; aluminum k=167, rho=2700, cp approximately900. The package has assumed k=20 W/mK and 1 J/K total capacity, because a real diode package has not been selected. The chamber is a single-phase copper-conductivity surrogate with assumed effective volumetric heat capacity 1.8 MJ/m3K. Vapor startup, wick orientation, transport limits and dryout are not modeled. The inherited chamber-to-fin-carrier gap is 0.25 mm. The study explicitly inserts a 0.25 mm k=3 W/mK pad there, plus a 0.05 mm k=3 W/mK bridge interface. These are assumptions requiring material selection and contact-pressure testing. The added pad appears in the study geometry; heat was not conducted through an unmodeled air gap. First-pulse case maximum is about 25.86 C at t=0.10 s. After pulse 60 it is about 28.47 C at t=59.10 s, cooling to 27.68 C at 60.0 s. Total input is 52.80 J, rejected heat 11.32 J, and stored energy 41.48 J. Relative energy residual is 1.7e-13. Spatial refinement changes first-pulse temperature rise by 0.960% and time refinement by 0.146%. These checks are numerical consistency checks; they do not validate unknown physical inputs. Package capacity 0.5–2 J/K changes the first-pulse peak to approximately 25.44–26.58 C. Airflow assumptions also change the long-train result. This is a package/cooling-path calculation; junction transient impedance, laser-driver loss, processor/camera heat, sunlight, enclosure coupling and real vapor-chamber behavior remain outside the result. TEMPERATURE AND COLOR MAPPING First-pulse view: 25–26 C. Pulse-train view: 25–29 C. These scales are visible and intentionally different. Barycentric sampling uses the actual P1 tetrahedra. At CAD surface points outside a voxelized boundary, nearest nodal recovery is used; counts per part are in field_mapping.json. The sub-tessellated CAD surface preserves its shape and is used only to display the computed scalar. It is not a separate CFD or FEA calculation. PRIMARY SOURCES AND METHODS scikit-fem linear elasticity example: https://github.com/kinnala/scikit-fem/blob/master/docs/examples/ex11.py scikit-fem heat equation / Robin heat transfer examples: https://scikit-fem.readthedocs.io/en/stable/listofexamples.html NIST 6061-T6 material reference: https://www.nist.gov/mml/acmd/aluminum-6061-t6-uns-aa96061 Kaiser 6061 sheet/plate typical properties (k167 T6, density2700; cp896 quoted at100C, rounded here): https://online.kaiseraluminum.com/depot/PublicProductInformation/Document/1015/Kaiser_Aluminum_6061_Sheet_Coil_and_Plate.pdf KME Cu-ETP typical properties at20C (k394, rho8920, cp394): https://www.kme.com/fileadmin/DOWNLOADCENTER/COPPER%20DIVISON/4%20Industrial%20Rolled/3_Datasheets/Datasheets_NEW_2021/Cu-ETP_01_2021_e.pdf Source design/power basis: outputs/references/optical_head_revC/Design_review.md. The support stiffness, convection, package capacity, interface pads and chamber surrogate remain assumptions. REPRODUCTION Working scripts: work/photonic_fea/. Copies are provided in source/. Python3.11 with NumPy, SciPy, scikit-fem12.0.2, Matplotlib, Pillow; Blender5.2.2; ffmpeg. Order: extract_geometry.py -> structural.py / thermal.py -> visual_fields.py -> render_analysis.py -> compose.py. The isolator sensitivity script is also included. Run report.py to regenerate this explanation and check figure. Scripts assume the existing workspace and original outputs/photonic_hero/ source movie/scene remain available. The delivered frozen .blend is self-contained. It opens in the thermal study; the named mounting camera, mounting objects and computed carrier field are also retained for editing via their render-visibility toggles. OPTICAL GEOMETRY REVISION — 23 OCTOBER 2026 The expanded film and editable scene include the three lens-housing axis correction. See ../photonic_hero/lens_alignment_check.json. Structural and thermal fields are unchanged.